Use this heat index calculator
Enter the air temperature and relative humidity to calculate the heat index. Or enter your ZIP code to auto-fill both values from live weather data for your location.
Auto-Fill by ZIP Code
Use a US ZIP code to prefill current weather inputs
We'll look up the matching location and populate temperature and relative humidity for you.
The heat index is calculated for shaded conditions using the NWS Rothfusz regression, which carries a stated accuracy of roughly ±1.3°F. Full sunlight can raise the effective heat stress by up to 15°F above the calculated value. For occupational or athletic heat safety decisions governed by OSHA, NATA, NCAA, or state athletic association policy, use Wet Bulb Globe Temperature measured on site.
Why a weather monitoring company built a heat index calculator
This calculator implements the National Weather Service formula correctly. But the formula has a built-in assumption that almost nobody mentions, and it changes how the number should be used: the heat index describes shaded conditions with a light wind.
That is not a minor caveat. NWS states that exposure to full sunshine can increase heat index values by up to 15°F. A calculated heat index of 95°F — Extreme Caution — describes something closer to 110°F, well into the Danger band, for a crew working on open asphalt. The formula also assumes a specific body type, a specific activity level, and a light breeze, none of which describe a lineman in pads or a roofer at noon.
That gap is why cyclonePORT exists. Our weather stations measure temperature and humidity at your actual site, and they also measure Wet Bulb Globe Temperature — the metric that incorporates solar radiation and wind, and the one OSHA, NATA, the NCAA, and state athletic associations actually specify for heat safety decisions. Heat index is the right number for a forecast. WBGT is the right number for a decision.
When a calculator is enough — and when it isn't
A heat index calculator is genuinely useful for: understanding a forecast, deciding what to wear, planning a run or a yard project, or explaining to someone why 88°F in Houston feels worse than 95°F in Phoenix.
It is not sufficient for: setting work/rest cycles for an outdoor crew, deciding whether a practice proceeds, documenting conditions for a heat illness investigation, or any decision governed by a standard that specifies WBGT. The gap is not the arithmetic — it is that heat index excludes sun and wind, describes a point you did not measure, and leaves no record.
What is heat index?
Heat index is how hot it feels when relative humidity is combined with air temperature. It is an apparent temperature — the shade temperature that would produce the same physiological heat stress as the actual temperature and humidity together.
The mechanism is evaporative cooling. Your body sheds heat primarily by sweating, and sweat only cools you when it evaporates. As humidity rises, the air holds more water vapor and evaporation slows, so the same air temperature removes less heat from your body. At 95°F with 20% humidity sweat evaporates freely; at 95°F with 70% humidity it does not, and your core temperature climbs.
The simple version
90°F with 40% humidity gives a heat index of 91°F — essentially the air temperature. The air is dry enough that sweating works normally.
90°F with 70% humidity gives a heat index of 106°F. Same thermometer reading, 15 degrees of additional effective heat stress, because evaporation has slowed.
Heat index is never meaningfully below the air temperature in hot conditions, and in very dry air it can read slightly below it — dry air improves evaporative cooling.
Where the heat index came from
The idea reached the public through a television weatherman. In 1978, George Winterling, chief meteorologist at WJXT in Jacksonville, coined the term humiture to explain to his viewers why Florida summers felt so much worse than the thermometer suggested. The National Weather Service adopted the concept the following year and renamed it the heat index.
The science underneath it is R.G. Steadman's 1979 paper The Assessment of Sultriness, which modeled the human body as a set of heat balance equations across roughly twenty variables. In 1990, Lans P. Rothfusz of the NWS Scientific Services Division fitted a nine-term polynomial regression to the hot portion of Steadman's resulting table so the values could be computed rather than looked up. That regression is what weather services use today, and it is what this calculator implements.
Meet the person the heat index was written for
To isolate temperature and humidity from everything else, Steadman invented a specific hypothetical person: someone 5 feet 7 inches tall, weighing 147 pounds, walking at about 3.1 miles per hour in a light breeze, wearing long pants and a short-sleeved shirt, in the shade.
Every heat index value you have ever seen describes that person. A 280-pound lineman in full pads doing gassers on turf at noon is not that person, and neither is a roofer in long sleeves on a black membrane. The further your situation sits from Steadman's walker, the more the number understates what is actually happening.
The shade assumption most people miss
Every published heat index value — on this page, on weather.gov, in your weather app — assumes the person is in the shade. The National Weather Service is explicit that exposure to full sunshine can increase heat index values by up to 15°F.
This matters because the people most affected by heat are rarely in shade. A construction crew, a landscaping team, a marching band on a practice field, a roofer, a farmworker — all of them are in direct sun for most of the exposure period, and all of them are experiencing heat stress meaningfully higher than the published number.
What the formula also assumes
Beyond shade, the Steadman model behind the heat index assumes a light breeze, a particular body size, walking-pace activity, and ordinary clothing. Change any of those and the number understates the real exposure.
A worker in impermeable PPE, a lineman in full pads, or anyone doing heavy physical labor in still air is operating well outside the model's assumptions. This is the central reason occupational and athletic heat standards specify Wet Bulb Globe Temperature instead — WBGT measures solar load and wind directly rather than assuming them.
How to calculate heat index
The NWS uses a two-step algorithm. Most online calculators implement only the second step, which produces wrong answers at the low end and at humidity extremes.
Step 1 — the simple check
Steadman simple form:
Average this result with the air temperature. If that average is below 80°F, it is the heat index and you stop here. The full regression was fitted to the hot end of Steadman's table and overshoots at lower temperatures.
Step 2 — the Rothfusz regression
If the simple average is 80°F or above, use the nine-term regression:
T is air temperature in °F and RH is relative humidity as a whole number (70, not 0.70). The coefficients have no individual physical meaning — they are the output of a regression fit.
Step 3 — the two adjustments
These are the terms most calculators omit, and they matter at the extremes:
Dry air — when RH is below 13% and T is between 80°F and 112°F, subtract:
Humid air — when RH is above 85% and T is between 80°F and 87°F, add:
Worked example
Air temperature 90°F, relative humidity 70%:
- Simple form: 0.5 × [90 + 61 + (22 × 1.2) + (70 × 0.094)] = 0.5 × 183.98 = 91.99
- Average with air temperature: (91.99 + 90) ÷ 2 = 90.99 — above 80, so continue to the regression
- Apply the nine terms with T = 90 and RH = 70
- Neither adjustment applies (RH is between 13% and 85%)
- Result: 106°F — matching the published NWS chart value exactly
That is 16 degrees above the air temperature, and it is the shade figure. In full sun the same conditions could approach 120°F of effective heat stress.
NWS heat index risk levels
The National Weather Service groups heat index values into four categories, each with a described likelihood of heat disorders for people in that environment.
Fatigue is possible with prolonged exposure and physical activity. Most healthy people tolerate this range well with normal hydration, but it is where outdoor workers and athletes should begin structured water breaks.
Heat cramps and heat exhaustion are possible, and continued activity could lead to heat stroke. Work/rest cycles, shade access, and active monitoring of at-risk individuals become necessary rather than optional.
Heat cramps and heat exhaustion are likely, and heat stroke is possible with prolonged exposure and activity. Non-essential outdoor work should be rescheduled. Anything that continues needs frequent rotation, mandatory rest in shade or air conditioning, and someone watching for symptoms.
Heat stroke is highly likely. Outdoor exposure should be eliminated except where unavoidable, with cooling capability immediately available on site.
Dry heat is not safe heat
In very dry air the heat index sits close to — or slightly below — the air temperature, because evaporation works efficiently. That can create a false sense of security. Efficient evaporation means rapid fluid loss, and dehydration sets in faster than people expect precisely because sweat disappears before it is noticed.
A 105°F day at 12% humidity produces a modest heat index, and still requires aggressive hydration, shade access, and the same monitoring a humid day would get.
Remember the shade adjustment when applying these bands
A crew working in full sun at a calculated heat index of 95°F — the middle of Extreme Caution — may be experiencing conditions equivalent to 110°F, which is solidly in the Danger band. The category you read off a forecast is not the category your people are in.
Heat index chart
This chart shows the calculated heat index in °F for combinations of air temperature and relative humidity, shaded by NWS risk category. Find your air temperature on the left, then read across to your relative humidity.
A note on the extremes: physicists Yi-Chuan Lu and David Romps have shown that the Rothfusz regression is frequently applied beyond the range Steadman's model actually supports, and that doing so can under-estimate the heat index at very high temperatures. That is a further reason to treat values far outside the common range as indicative rather than precise.
The greyed cells in the upper right are combinations that do not occur on Earth. A relative humidity of 100% at 104°F would require a dew point of 104°F; the highest dew point ever reliably recorded is around 95°F. The official NWS chart truncates the same corner for the same reason, and any calculator that cheerfully reports a heat index of 250°F is extrapolating a regression far past the data it was fitted to.
Heat index vs. WBGT and wet bulb temperature
These three get used interchangeably and they are not the same thing. The distinction decides which number your compliance obligation actually references.
| Heat index | Wet bulb temperature | WBGT | |
|---|---|---|---|
| What it combines | Temperature + humidity | Temperature + humidity, as the lowest temperature reachable by evaporation | Temperature + humidity + solar radiation + wind |
| How it's produced | Calculated from two inputs | Measured with a wetted thermometer, or calculated | Measured with three sensors: dry bulb, natural wet bulb, black globe |
| Accounts for sun | No — assumes shade | No | Yes — that is the black globe's purpose |
| Accounts for wind | Assumes a light breeze | Partially | Yes, directly |
| Typical use | Public forecasts and advisories | Survivability research, meteorology | Occupational and athletic heat safety compliance |
| Non-US equivalent | Humidex, used by Environment and Climate Change Canada, computes from dew point rather than relative humidity and tends to run higher in humid coastal conditions | Used internationally as-is | Used internationally, including by the US military and ACGIH |
| Named in standards | Referenced in OSHA's proposed heat rule as one permitted metric | Rarely | Specified by NATA, NCAA, the US military, ACGIH, Texas UIL, and most state athletic associations |
The practical rule: heat index is the public-facing metric, WBGT is the compliance metric. If a standard governs your decision — an athletic association policy, an occupational heat program, a military work/rest table — it almost certainly specifies WBGT. If you are reading a forecast or an NWS advisory, you are looking at heat index.
They also diverge in opposite directions depending on conditions. In humid, shaded, low-wind conditions heat index and WBGT track reasonably well. In dry, sunny, breezy conditions heat index can substantially understate the radiant load while overstating the humidity effect. That divergence is why the two metrics are not interchangeable even as rough approximations.
Try the cyclonePORT WBGT Calculator →
Who faces higher risk than the number suggests
The heat index is an environmental measurement, not a personal one. It describes conditions, and Steadman's model assumed one particular healthy adult. Several groups experience meaningfully more strain at the same reading.
- Children. A child's surface-area-to-body-mass ratio differs from the adult the model assumes, and younger children sweat less efficiently and acclimatize more slowly. They also do not reliably self-report early symptoms.
- Older adults. Thermoregulation and thirst response both decline with age, and chronic conditions become more common.
- People with cardiovascular or pulmonary conditions, whose bodies have less capacity to increase skin blood flow and cardiac output in response to heat.
- People taking medications that impair sweating or circulation — diuretics, antihistamines, beta blockers, and stimulants among them.
- Pregnant individuals, who carry additional metabolic load and have altered fluid balance.
- Anyone working at high exertion, since metabolic heat generated internally adds to the environmental load the index describes.
- Anyone in heavy, non-breathable, or protective clothing, which traps a layer of hot humid air against the skin and blocks the evaporation the whole index is premised on.
For these groups, a lower heat index should trigger the precautions the chart assigns to a higher band. Waiting for the Danger threshold is the wrong approach when the person in front of you is outside the model.
Why heat index matters for operations
In each case below, the pattern repeats: the decision depends on conditions at the specific site, updated continuously, with a record of what they were.
Construction and outdoor trades
OSHA has no finalized federal heat standard, but the General Duty Clause applies and the agency's National Emphasis Program authorizes inspections on heat advisory days. OSHA's proposed rule framework uses an initial trigger at a heat index of 80°F and a high-heat trigger at 90°F, with WBGT accepted as an equivalent metric.
What this requires: measurement at the work location, since a crew on open asphalt is in conditions the shaded forecast figure does not describe.
Athletics and marching band
Athletic heat policy has largely moved to WBGT. NATA's Exertional Heat Illnesses position statement specifies it, and Texas UIL made WBGT monitoring mandatory for all outdoor athletic and marching band activity as of August 1, 2026. Heat index remains useful context but is no longer the governing number in most states.
What this requires: an actual WBGT instrument or an approved equivalent, not a heat index reading used as a substitute.
Agriculture
Farmworkers face the highest heat-related mortality rate of any US occupational group. California, Oregon, Washington, Colorado, Maryland, Minnesota, and Nevada have enforceable heat standards, several of which use heat index triggers at 80°F and 90°F for shade, water, and rest requirements.
What this requires: field-level measurement, since a large operation can span microclimates, and documentation that triggers were met.
Facilities and indoor heat
Warehouses, kitchens, foundries, and laundries can run far hotter than ambient. California's indoor heat standard takes effect at 82°F indoors. Heat index is computable indoors from temperature and humidity, and indoor conditions are often more stable and therefore easier to characterize than outdoor ones.
What this requires: sensors in the work area rather than in the office, and awareness that process heat can create large gradients within one building.
What on-site measurement adds
cyclonePORT measures temperature and humidity at your location and computes heat index in real time — along with WBGT, using a black globe sensor, natural wet bulb, and dry bulb sensor, which is the measurement occupational and athletic standards actually specify.
Sensor siting matters as much as the sensor. A unit mounted near a wall, over asphalt, or above a roof membrane reads high; one in a shaded courtyard reads low. Urban heat island effects and poor placement are documented sources of systematic error in city temperature records, and the same physics applies to a single jobsite.
Threshold alerts reach the whole team simultaneously when a configured level is crossed, and every reading is logged automatically with a timestamp. That log is what answers the question after a heat illness incident: what were the conditions, and when did you know.
Frequently asked questions
What is heat index?
Heat index is an apparent temperature that combines air temperature and relative humidity into a single "feels like" value. It represents the shade temperature that would produce the same physiological heat stress as the actual temperature and humidity together. The mechanism is evaporative cooling: your body sheds heat mainly by sweating, and sweat only cools you when it evaporates. As humidity rises, evaporation slows, so the same air temperature removes less heat from your body. At 90°F with 40% humidity the heat index is 91°F; at 90°F with 70% humidity it is 106°F.
How do you calculate heat index?
The National Weather Service uses a two-step method. First compute the Steadman simple form: HI = 0.5 × [T + 61.0 + ((T − 68.0) × 1.2) + (RH × 0.094)], then average the result with the air temperature. If that average is below 80°F, it is the heat index. If it is 80°F or above, use the Rothfusz nine-term regression: HI = −42.379 + 2.04901523T + 10.14333127RH − 0.22475541(T)(RH) − 0.00683783T² − 0.05481717RH² + 0.00122874T²RH + 0.00085282T(RH²) − 0.00000199T²RH², with T in °F and RH as a whole number. Two adjustments then apply at the extremes: subtract ((13 − RH)/4) × √((17 − |T − 95|)/17) when RH is below 13% and T is 80 to 112°F, and add ((RH − 85)/10) × ((87 − T)/5) when RH is above 85% and T is 80 to 87°F.
Does the heat index account for direct sunlight?
No, and this is the most important limitation of the metric. Every published heat index value assumes shaded conditions. The National Weather Service states that exposure to full sunshine can increase heat index values by up to 15°F. A calculated heat index of 95°F, which falls in the Extreme Caution band, may represent conditions closer to 110°F — solidly in the Danger band — for someone working in direct sun. The underlying Steadman model also assumes a light breeze, a specific body size, walking-pace activity, and ordinary clothing, so heavy labor, protective equipment, or athletic padding all push real heat stress above the calculated figure.
What is the difference between heat index and WBGT?
Heat index combines only temperature and humidity and assumes shade. Wet Bulb Globe Temperature combines temperature, humidity, solar radiation, and wind, measured directly with three sensors: a dry bulb, a natural wet bulb, and a black globe that captures radiant heat load. The practical distinction is that heat index is the public-facing metric used in forecasts and NWS advisories, while WBGT is the compliance metric specified by NATA, the NCAA, the US military, ACGIH, Texas UIL, and most state high school athletic associations. The two diverge most in dry, sunny, breezy conditions, where heat index understates radiant load. If a standard governs your decision, check which metric it names — substituting one for the other is not a safe approximation.
What is the difference between heat index and wet bulb temperature?
Wet bulb temperature is the lowest temperature air can reach through evaporative cooling alone — physically, the reading of a thermometer with a wet wick over it in moving air. It is a measurement of the air's cooling capacity, and it is used in survivability research because a sustained wet bulb temperature near 95°F exceeds what the human body can shed heat against regardless of hydration or shade. Heat index is different: it is a calculated apparent temperature expressing how hot conditions feel, derived from temperature and humidity through a regression fitted to a physiological model. Wet bulb temperature is also one of the three inputs to WBGT, which is different again from plain wet bulb.
What heat index is dangerous?
The National Weather Service uses four bands. Caution covers 80 to 90°F, where fatigue is possible with prolonged exposure and activity. Extreme Caution covers 90 to 103°F, where heat cramps and heat exhaustion are possible and continued activity could cause heat stroke. Danger covers 103 to 124°F, where heat cramps and heat exhaustion are likely and heat stroke is possible. Extreme Danger is 125°F and above, where heat stroke is highly likely. Apply these with the shade caveat in mind: a crew in full sun at a calculated 95°F may be experiencing conditions equivalent to the Danger band.
How accurate is the heat index formula?
The Rothfusz regression carries a stated accuracy of approximately ±1.3°F, which Rothfusz noted in the original 1990 NWS technical attachment. That figure describes how closely the polynomial reproduces Steadman's underlying table — it does not describe how well the result matches any individual's experience, since the model assumes particular clothing, body dimensions, and activity. The larger sources of error in practice are the shade assumption, the inputs themselves if they come from a distant weather station rather than your location, and extrapolation past the range the regression was fitted to.
Why do some heat index calculators give different answers?
Usually because they skip part of the NWS algorithm. The full method has three components: a simple Steadman check that governs below 80°F, the Rothfusz regression above it, and two adjustment terms for very dry and very humid conditions. Many online calculators implement only the regression, which overshoots at lower temperatures because it was fitted to the hot end of Steadman's table. Others omit the dry-air and humid-air adjustments, producing errors of several degrees at the extremes. Rounding conventions and whether humidity is entered as a whole number or a decimal account for smaller differences.
Can the heat index be lower than the air temperature?
Yes, in dry air. When relative humidity is low, evaporation is efficient and the body cools more readily than it would at moderate humidity, so the apparent temperature falls slightly below the thermometer reading. The NWS dry-air adjustment formalizes this: below 13% relative humidity, between 80 and 112°F, a subtraction is applied. At 100°F with 5% humidity, the heat index works out to roughly 93°F. In humid conditions the heat index is always equal to or higher than the air temperature.
Do I need a weather station, or is a heat index calculator enough?
A calculator is sufficient for understanding a forecast, planning personal activity, or explaining why one climate feels worse than another. It is not sufficient when the number drives an operational decision, for three reasons specific to heat.
First, the heat index assumes shade, and the people whose safety depends on the number are usually in sun — a gap of up to 15°F. Second, most heat safety standards specify WBGT rather than heat index, and WBGT cannot be derived from temperature and humidity alone because it requires measuring solar radiation and wind. Third, heat illness investigations turn on what conditions were and when, which requires a timestamped record rather than a calculation someone ran once. If your heat question involves work/rest cycles, athletic practice decisions, or documented compliance, you need on-site measurement of WBGT, not a heat index figure.
Measure the heat your people are actually in
cyclonePORT computes heat index and WBGT in real time from calibrated sensors at your site — capturing the solar load and wind that a heat index calculation leaves out.
Contact our team · 1-844-CYCLONE · support@cycloneport.com